• Flexible Dental Files Holder K-File Handle Hand Use Posterior Root Canal Clip
  • Flexible Dental Files Holder K-File Handle Hand Use Posterior Root Canal Clip
  • Flexible Dental Files Holder K-File Handle Hand Use Posterior Root Canal Clip
1/1
  • Flexible Dental Files Holder K-File Handle Hand Use Posterior Root Canal Clip
  • Flexible Dental Files Holder K-File Handle Hand Use Posterior Root Canal Clip
  • Flexible Dental Files Holder K-File Handle Hand Use Posterior Root Canal Clip

Flexible Dental Files Holder K-File Handle Hand Use Posterior Root Canal Clip

SKU: VZ004806
0.0 (0 Reviews)
$12.50 $9.50
Received successfully
Coupon Code
CONTINUE SHOPPING
Discount
  • GET $25.00 OFF ON ORDERS OVER $500.00
  • GET $60.00 OFF ON ORDERS OVER $1,000.00
    Please select the information you want X
  • Color:
    Blue
    Grey
Quantity
-
+
  • Flexible Dental Files Holder K-File Handle Hand Use Posterior Root Canal Clip
  • Flexible Dental Files Holder K-File Handle Hand Use Posterior Root Canal Clip
  • Flexible Dental Files Holder K-File Handle Hand Use Posterior Root Canal Clip
  • Description
Endo Files Clamp Holder
(User Manual)
Function: Used for hold endo files during endodontic treatment.
User manual: Endo files clamp holder can hold the files handletightly by rotating the fxing screw.
Cautious:
1. The instrument is non-sterilize, before use it have to be sterilied. Recommend sterilize with high temperature or high pressure.
2. For automatic cleaning/Autoclave:
● Put the instrument in right position(unfold the instrument completely especially the narrow or long connection part.)
● Can only use the proper cleaning agent/ disifectant for the cleaning and disinfection. For the quantity of cleaning agent/ disinfectant needed, please reference to the instruction of the
cleaning agent/ disinfectant used.
● To ensure clean out the instrument, cleaning needs at least 10 minutes.
●After the cleaning and disinfection, instrument should be dried in time.
● Take out the instrument from cleaner after the cleaning, do not leave the instrument in cleaner for whole night.
3. For manual cleaning (Only used when there is no automatic cleaner)
● Use proper cleaning agent and brushes (do not use metal brushes), clean the instrument with flowing water completel, make sure the instrument is tally leaned. · Use soft clothes clean the surface and keep instrument dry.
4. Change the defect instrument on time(ex. Crackle, deformed)
5. Instrument made by stainless stee can't put into the saline solution (like NaCl), long time contact with the solution may cause crackle.
6. Operator should be responsible for the instrument, material used in the operation, and the expected results.Normallyit requires to reconfirm about the operation andaily monitoring. 7. Before disposal of waste, item should be cleaned, autoclave and sterilized. 8. Endo fles clamp holder should keep away from Corrosive drugs. 9. Endo fle clamp holder can only be operated by profssional dentsts.
Storage: Endo files clamp holder should be stored in environment relatve humidity no more than 80%, non corrosive gas, clean room with good ventilation. Manufacturer Date: refer to product package label. Life Span: Uncertain
Frequently Bought Together
more
Frequently Bought Together
CUSTOMER REVIEWS
0.0 0 Reviews
Write a review